Contemporary Two Storey 2018-01-09T15:47:21+00:00

Project Description

Contemporary Two Storey

ECOHOUSE TWO STOREY CONTEMPORARY HOUSE

Brief

Our contemporary two storey homes are built to the highest standards, using sustainable and eco-smart materials that stand the test of time. Our in-house team of designers, architects and builders are involved from day one; from arranging planning permission to executing the finer interior design details.

We build bright spacious homes that reflect your lifestyle and meet your needs; always focused on the vision you have in mind. Our homes boast remarkable energy savings and the highest quality material, all while remaining cost effective.

  • Size: 21.9m x 14.4m (71.8ft x 47.2ft)

  • Living Area 188.8m² (2032 sq ft)

  • Total Floor Area 315.3m² (3393 sq ft)

Self Build

Delivery and erection of frame only

Passive house structure

External wall U-Value 0.126 W/m2K

  • Breathable membrane
  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 200mm
  • Airtight membrane
  • 50mm service cavity 50x25mm stud filled with 50mm Knauf naturboard (supply only)

Internal partitions

  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 120mm

Intermediate floors

  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 202mm

Roof U-Value 0.124 W/m2K

  • 50x25mm vertical air flow chase
  • Roof breathable membrane
  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 200mm
  • Airtight membrane
  • 75mm service cavity 50x25mm stud filled with 75mm Knauf naturboard (supply only)

Full Build

Complete passive house package
  1. Passive slab foundation U-Value 0.10
  • Insulated raft foundation
  • Slab floated ready for tiling
  • Underfloor heating pipes and manifold
  • 1st fix plumbing, waste & drainage
  1. Passive house structure 

External wall U-Value 0.126 W/m2K

  • Breathable membrane
  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 200mm
  • Airtight membrane
  • 50mm service cavity 50x25mm stud filled with 50mm Knauf naturboard (supply only)

Internal partitions

  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 120mm

Intermediate floors

  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 202mm

Roof U-Value 0.124 W/m2K

  • 50x25mm vertical air flow chase
  • Roof breathable membrane
  • Pre-engineered Post & Beam Glue Lam construction with Structural Insulated Panels (SIP) 200mm
  • Airtight membrane
  • 75mm service cavity 50x25mm stud filled with 75mm Knauf naturboard (supply only)

All above meets passive house standard 

  • Air tightness below 63/hm2@50pa
  • Thermal bridge free <01

Achieves :

  • Up to 90% reduction in heating requirements
  • Up to 100% reduction in CO2
  1. Roofing System
  • Selected roofing (Slate, Tegral composite)
  • Steel profile where applicable
    50x25mm roof battens @ 450 centres
  • uPVC Gutter, fascia & ventilated soffit
  1. External Finish
  • Baumit external render system / Stone cladding were applicable
  • 10mm Tegral fibre cement board
  • 5mm vertical aluminium profile
  1. Internal Finish
  • Ceilings, walls 12.5mm gypsum board (plastered ready for painting
  1. Windows & doors

External Windows & Doors

  • Composite main entrance door, design TBC
  • Triple glazing U-Value as low as 0.65W/m2K
  • Inward opening
  • Wheelchair threshold
  • Secure multi-point locking system
  • Satin chrome ironmongery
  • Passive range triple glazed wooden windows U-Value as low as 0.65W/m2K
  • Skylights
  • Factory painted in any RAL colour

Internal doors

  • Mdf laminate doors and glazed doors
  • Pre-fabricated, untreated pine door frame sets with acoustic seals and architraves
  • Brushed chrome hinges & handles
  1. Pine staircase (where aplicable) 
  1. Electrical
  • All connections needed for MVHR system & Air – water heat pump
  • Fuse board
  • Hallway & landing, 2x light points, 2x one gang switches, 2x double sockets
  • Utility room, 1x light point, 1x one gang switch, 2x double sockets
  • Bathroom & en suite, 1x light point, 1x one gang switch, 1x mirror light & 115v socket
  • Kitchen includes, 2x light points, 1x two gang switch & 7x double sockets
  • Living room includes, 2x light points, 1x two gang switch, 5x double sockets & data point
  • Bedrooms includes, 1x light point, 1x one gang switch & 2x double sockets
  • First & second fix, standard fittings

     9. Heating & Plumbing

  • Panasonic Aquarea air to water heat pump
  • Panasonic Aquarea low temperature radiators (first floor)
  • First fix plumbing, ready for sanitary ware, kitchen sink and appliances

  10. MVHR Mechanical ventilation heat recovery

  • Komfovent Domekt system
  • Komfovent C4.1 touch screen control panel
  • Compatible with smart devices

Not included:

Internal

  • Kitchen & appliances
  • Sanitary ware
  • Flooring & skirting boards
  • Painting

Please note:

  • Foundation price is subject to site visit

Ready to Talk?

DO YOU HAVE A BIG IDEA WE CAN HELP WITH?

Contact Us